Short answer
California's Wildland-Urban Interface Code requires a spark arrestor of 12-gauge wire mesh with openings no larger than one-half inch on wood-burning chimneys in the areas it covers. Near Novato's open space, a wood-burning chimney should carry one, with no tree limb within 10 feet of the outlet and no leaves on the roof. On Red Flag days and dry, gusty offshore evenings, leave the fireplace unlit.
Why a chimney spark arrestor matters in a Novato fall
A chimney spark arrestor is a simple metal screen, and in Novato it does some of its most important work in October. A good share of the city ends at a fire road or an open space gate: San Marin sits below Mount Burdell, streets in Indian Valley and Ignacio Valley run up to county open space preserves, and Marinwood climbs toward Big Rock Ridge. By fall, the grass and oak woodland on those slopes have gone months without rain. The National Weather Service describes peak fire weather in the Bay Area as running from late summer into early fall, when offshore flow is most common and the dry season is ending.
That is also when the first cool evenings make a fire tempting. Offshore wind blows from the dry interior toward the coast instead of bringing damp ocean air inland, and when it turns strong over the hills it is known locally as the Diablo wind. A wood fire sends sparks and burning flakes up the flue on any night. On a dry, gusty one, whatever clears the chimney top can travel. The screen keeps those embers inside the cap until they burn out, and it works in the other direction too, keeping wind-blown embers from a nearby fire from dropping into an open flue.

What California code requires of a chimney spark arrestor
California gathered its wildfire building rules into a single book for the current code cycle. The 2025 California Wildland-Urban Interface Code, Title 24, Part 7, took effect on January 1, 2026. Its Section 605 requires a spark arrestor on chimneys serving fireplaces, barbecues, incinerators or decorative heating appliances that burn solid or liquid fuel, and it spells out what qualifies:
- Material: woven or welded wire screening made of 12-gauge wire, far heavier than window screen.
- Openings: no larger than one-half inch.
- Net free area: at least four times the net free area of the chimney outlet, so the screen does not choke the flue.
The same code's voluntary home-hardening appendix adds a lower bound, recommending noncombustible, corrosion-resistant metal mesh with openings from three-eighths to one-half inch. Two state laws cover the space around the chimney. Public Resources Code 4291, for the state responsibility area, and Government Code 51182, for very high fire hazard severity zones designated by local agencies, both require owners to remove any part of a tree within 10 feet of a chimney or stovepipe outlet and to keep the roof free of leaves, needles and other plant material.
Which of these rules applies to a given lot depends on its fire hazard designation and the local fire code, so the Novato Fire District is the right authority for questions about a specific address. In practice, a wood-burning chimney anywhere near North Marin's open space should carry a compliant screen, and our chimney cap and spark arrestor installation page explains how we fit one.
What a compliant spark arrestor looks like on the roof
From the street, a working arrestor reads as a metal cage at the top of the flue with a solid lid above it. Up close, a few details separate a screen that does its job from one that only looks the part:
- Mesh on every side, with no gaps at the corners or where the screen meets the flue tile, crown or chase top. An ember only needs one opening.
- Stiff, heavy wire that holds its shape. Light hardware cloth or a cut piece of window screen sags, clogs and rusts through.
- Openings in the three-eighths to one-half inch range. Finer mesh catches soot and creosote quickly and starts to restrict draft; coarser mesh lets embers out.
- Stainless steel or another corrosion-resistant metal. Galvanized screens eventually rust thin and open holes.
- Every flue covered. On a brick chimney with two or three flues, one capped flue next to an open one still leaves a path for sparks.
Factory-built chimneys, which top the framed chases on many homes in Novato's later subdivisions, are a separate case. Their termination cap is part of a tested, listed system, so the spark screen should be the one the manufacturer specifies for that model rather than a generic cage clamped over the pipe. Gas fireplaces vent through their own listed terminations, and the spark arrestor section is written for chimneys that burn solid or liquid fuel. Chimney Services Pro confirms which type you have before recommending any part.
Checking the cap and screen before the first fall fire
Start from the ground. Binoculars from the yard or across the street will show whether the cap still sits square on the flue, whether any panel of mesh is torn, bent or missing, and whether a dark crust has built up on the screen. Look again after the first windy stretch of the season, since gusts coming over the ridges are hard on caps that were never fastened well.
A clogged screen is easy to overlook and worth taking seriously. Creosote and fly ash collect in the mesh, and the buildup is fastest above wood stoves run low and slow for long burns, which are common on the larger lots out Novato Boulevard and in Indian Valley. A screen packed with deposits slows the draft so smoke drifts back into the room, and the deposits themselves can ignite. That is a job for a sweep, not a wire brush on a steep hillside roof.
During a chimney inspection we look at the arrestor up close: mesh size and condition, fasteners, the seal between the cap and the crown or chase top, and the clearance around the outlet. The visit also covers the flue below, because a screen only helps if the fire under it is burning cleanly. When the mesh is loaded with deposits, a chimney sweep clears the screen and the flue in one trip.
Roof, gutter and branch debris around the chimney
The area around the chimney matters as much as the screen itself. Novato's oaks and bay trees shed leaves onto roofs, and the low spots collect them: the valley behind a wide brick chimney, the gutter run below it and the corners where a chase meets the roof. A dry drift of oak leaves a few feet from the outlet is exactly the fuel an escaped spark needs. Before the fireplace season starts:
- Cut back any branch within 10 feet of the chimney outlet, measured in every direction, including limbs that hang above the cap.
- Clear leaves and needles from the roof, the roof-to-wall corners and the gutters, then check again after the next windy week.
- Look behind the chimney. A cricket, the small peaked diverter on the uphill side, sheds water and debris, while a wide chimney without one tends to hold a dam of leaves.
- Keep the firewood stack away from the house walls and off the deck.
Novato Fire and the Marin Wildfire Prevention Authority offer free home assessments in which a wildfire mitigation specialist reviews home hardening and the vegetation around the house and leaves a written report, which pairs well with a chimney visit.
Burning only when the weather allows
A sound screen does not make every evening a good one for a fire. The National Weather Service issues a Red Flag Warning when a critical fire weather pattern is under way or about to arrive, and its advice for those days is to be extremely careful with open flames. For a Novato household with a wood-burning fireplace, the simple rule is to leave it unlit on Red Flag days and on any dry, gusty evening when the wind is blowing offshore, warning or not. For the rest of the season, a few habits keep sparks to a minimum:
- Burn small, hot fires of seasoned hardwood rather than large loads.
- Never burn paper piles, cardboard boxes or yard trimmings, which loft burning pieces straight up the flue.
- Keep the damper fully open while the fire burns and the glass doors or fireplace screen closed.
- Let ashes cool completely in a lidded metal can kept outdoors, well away from the house, decks and dry grass.
Once the rains arrive, the cap's main job becomes keeping water out. Our guide to winter storm chimney leaks picks up from there.